Product Detail

Model-led sourcing for maintenance, replacement and project requirements.

Industrial Automation Component

1FK7064-4CF71-1PH2

Siemens 1FK7064-4CF71-1PH2 is a SIMOTICS S synchronous motor with 2.5 kW, 3,000 rpm, 12 Nm, and resolver feedback. Confirm stock and dispatch conditions.

Reference1FK7064-4CF71-1PH2
Supply Statusin stock
Product Code
1FK7064-4CF71-1PH2
Weight
15.8 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet

Availability, condition, lead time, packing and commercial terms are confirmed for the submitted requirement.

01 / Product Features

Product Description

Key Features

  • PN=2.5kW: Rated power for the motor.
  • NN=3000rpm: Rated speed for the motor.
  • M0=12Nm (100K): Static torque value at 100 K.
  • UDC=600V: DC link voltage value stated for the motor.
  • Resolver R14DQ feedback: Resolver 14 bits with internal 2-pole encoder system.
  • IP65 and DE flange IP67: Degree of protection for the motor and DE flange.

Technical Summary

Product type SIMOTICS S Synchronous motor 1FK7-HD
Rated power 2.5 kW
Rated speed (100 K) 3,000 rpm
Static torque (100 K) 12.00 Nm
UDC 600V
Number of poles 6
Cooling Natural cooling
Degree of protection IP65 and DE flange IP67
Design acc. to Code I IM B5 (IM V1, IM V3)
Connector size M23
Encoder system Resolver R14DQ: resolver 14 bits (resolution 16384, internal 2-pole)
Holding brake version Permanent-magnet brake

Frequently Asked Questions

What is Siemens 1FK7064-4CF71-1PH2?

It is a SIMOTICS S synchronous motor 1FK7-HD.

What are the rated power and rated speed of 1FK7064-4CF71-1PH2?

Rated power is 2.5 kW and rated speed is 3,000 rpm.

What feedback and brake configuration does 1FK7064-4CF71-1PH2 have?

It has Resolver R14DQ feedback and a permanent-magnet brake.

What mounting and protection details are listed for 1FK7064-4CF71-1PH2?

The mounting design is IM B5 (IM V1, IM V3), and the degree of protection is IP65 and DE flange IP67.

02 / Supply and Quality Support

Supply Conditions

Send the exact model, quantity, destination and required condition. The quotation can then state the applicable supply and dispatch terms.

01

Exact Model Reference

Provide the complete Siemens order number or MLFB and the required quantity.

02

Condition and Scope

State the acceptable product condition and any documentation your company requires.

03

Packing and Dispatch

Destination and shipment needs are aligned before dispatch arrangements are confirmed.

04

Written Quotation

Current price, lead time, condition and commercial terms are stated for the request.