Key Features
- SINAMICS G120 CU240E-2 DP-F Control Unit: Control unit with E-type Safety Integrated STO and F-type SS1, SLS, SSM, SDI.
- PROFIBUS DP communication: Communication: PROFIBUS DP.
- I/O configuration: 6 DI, 3 DQ, 2 AI, 2 AQ, and max. 3 F-DI.
- Service interfaces: USB and SD/MMC interface.
- Protection and temperature: Degree of protection IP20 and ambient temperature 0 to +50 °C without Power Module.
Technical Summary
| Product type | SINAMICS G120 CU240E-2 DP-F Control Unit |
|---|---|
| Communication | PROFIBUS DP |
| Safety functions | Safety Integrated STO, F-type SS1, SLS, SSM, SDI |
| Standard digital inputs | 6 |
| Fail-safe digital inputs | 3 (Use of 6 × DI Standard) |
| Relays | 2 |
| Analog / digital inputs | 2 (Differential input) |
| Analog outputs | 2 (Non-isolated output) |
| Operating voltage via Power Module | DC 24 V |
| Operating voltage via external power supply | DC 20 … 29 V |
| Degree of protection | IP20 / UL open type |
Applications
- PROFIBUS DP drive communication: Integrates the control unit into a PROFIBUS DP communication network.
- Control and safety signal handling: Supports control and safety signal handling with 6 DI, 3 DQ, 2 AI, 2 AQ, and Safety Integrated functions.
Frequently Asked Questions
What is Siemens 6SL3244-0BB13-1PA1?
It is a SINAMICS G120 CU240E-2 DP-F Control Unit.
Which communication interface does 6SL3244-0BB13-1PA1 use?
Communication: PROFIBUS DP.
What I/O count is provided on 6SL3244-0BB13-1PA1?
It includes 6 DI, 3 DQ, 2 AI, 2 AQ, and max. 3 F-DI.
What power supply values are listed for 6SL3244-0BB13-1PA1?
Operating voltage via the Power Module is DC 24 V, and operating voltage via external power supply is DC 20 … 29 V.
What protection and temperature details are listed for 6SL3244-0BB13-1PA1?
Degree of protection is IP20 / UL open type, and ambient temperature for operation is -10 … 55 °C (14 … 131 °F).