Key Features
- Power and speed: PN=2kW and NN=3000rpm.
- Feedback system: ABSOLUTE ENCODER 24 BIT + 12 BIT MULTITURN WITH DRIVE-CLIQ INTERFACE (ENCODER AM24DQI).
- Mechanical configuration: FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1 with shaft with fitted key, tolerance N.
- Cooling and protection: Naturally cooled with Degree of protection IP65.
- Holding brake: with holding brake.
Technical Summary
| Product type | SIMOTICS S Synchronous motor 1FK7-HD |
|---|---|
| Rated power | PN=2kW |
| DC link voltage | UDC=600V |
| Static torque (100 K) | 22.00 Nm |
| Rated speed (100 K) | 3,000 rpm |
| Cooling | Natural cooling |
| Degree of protection | IP65 |
| Encoder system | Encoder AM24DQI: absolute encoder 24 bits (resolution 16777216, encoder-internal 2048 S/R) + 12 bits multi-turn (traversing range 4096 revolutions) |
| Holding brake | with holding brake |
| Design acc. to Code I | IM B5 (IM V1, IM V3) |
Frequently Asked Questions
What is Siemens 1FK7085-4CF71-1CB1?
It is a SIMOTICS S synchronous motor 1FK7-HD.
What are the key ratings for 1FK7085-4CF71-1CB1?
The motor is specified with PN=2kW, UDC=600V, M0=22Nm (100K), and NN=3000rpm.
Which feedback system is included with 1FK7085-4CF71-1CB1?
It includes an absolute encoder 24 BIT + 12 BIT MULTITURN WITH DRIVE-CLIQ INTERFACE (ENCODER AM24DQI).
What mechanical configuration does 1FK7085-4CF71-1CB1 have?
It has FRAME SIZE IMB 5 (IM V1, IM V3), FLANGE 1, shaft with fitted key, tolerance N, and with holding brake.
What should be confirmed before ordering 1FK7085-4CF71-1CB1?
Confirm the exact model, requested quantity, destination, stock, and dispatch conditions before ordering.