Product Detail

Model-led sourcing for maintenance, replacement and project requirements.

Industrial Automation Component

1FK7043-4CF21-1UA1

Siemens 1FK7043-4CF21-1UA1 SIMOTICS S synchronous motor with 3.0 Nm, 3000 rpm, IP65, DRIVE-CLiQ interface, and resolver feedback. Confirm stock and dispatch conditions before ordering.

Reference1FK7043-4CF21-1UA1
Supply Statusin stock
Product Code
1FK7043-4CF21-1UA1
Weight
6.002 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet

Availability, condition, lead time, packing and commercial terms are confirmed for the submitted requirement.

01 / Product Features

Product Description

Key Features

  • Performance ratings: PN=0.94kW, UDC=300V, M0=3.3Nm (100K), and NN=3000rpm.
  • Feedback and interface: Multi-pole resolver with DRIVE-CLiQ interface.
  • Mechanical and protection data: Naturally cooled, IMB 5 (IM V1, IM V3), IP65, shaft with fitted key, and without holding brake.

Technical Summary

Product designation 1FK7043-4CF21-1UA1
Motor type Permanent-magnet synchronous motor
High Dynamic High Dynamic
PN 0.94kW
UDC 300V
M0 3.3Nm (100K)
NN 3000rpm
Cooling Natural cooling
Degree of protection IP65
Encoder system Resolver R15DQ: resolver 15 bits (resolution 32768, internal multi- pole)
Electrical connectors Connectors for signals and power rotatable
Design acc. to Code I IM B5 (IM V1, IM V3)

Frequently Asked Questions

What is Siemens 1FK7043-4CF21-1UA1?

It is a SIMOTICS S synchronous motor.

What are the key ratings of 1FK7043-4CF21-1UA1?

PN=0.94kW, UDC=300V, M0=3.3Nm (100K), and NN=3000rpm.

What interface and feedback does 1FK7043-4CF21-1UA1 have?

It has a DRIVE-CLiQ interface and a resolver encoder system.

What mechanical configuration is specified for 1FK7043-4CF21-1UA1?

It has natural cooling, IMB 5 (IM V1, IM V3), a shaft with fitted key, and without holding brake.

What protection rating is specified for 1FK7043-4CF21-1UA1?

Degree of protection: IP65.

02 / Supply and Quality Support

Supply Conditions

Send the exact model, quantity, destination and required condition. The quotation can then state the applicable supply and dispatch terms.

01

Exact Model Reference

Provide the complete Siemens order number or MLFB and the required quantity.

02

Condition and Scope

State the acceptable product condition and any documentation your company requires.

03

Packing and Dispatch

Destination and shipment needs are aligned before dispatch arrangements are confirmed.

04

Written Quotation

Current price, lead time, condition and commercial terms are stated for the request.