Key Features
- Rack PC design: SIMATIC IPC647D in 19", 2U format.
- Interface set: 2x Gbit Ethernet (IE/PN), 1x DVI-I, 2x DisplayPort, 1x COM1, 2x PS/2, audio, and USB interfaces.
- Monitoring functions: Temperature monitoring, fan monitoring, and watchdog.
- Mounting: For horizontal installation; prepared for telescopic rails; 19" mounting bracket can be removed externally.
- Supply voltage: 100/240 V AC (autorange) 50 / 60 Hz; optional redundant 100/240 V AC.
Technical Summary
| Product type designation | IPC647D |
|---|---|
| Design | Rack PC, 19", 2U |
| Mounting | For horizontal installation; prepared for telescopic rails; 19" mounting bracket can be removed externally |
| Supply voltage | 100/240 V AC (autorange) 50 / 60 Hz; optional redundant 100/240 V AC |
| Mains/voltage failure stored energy time | 20 ms |
| Processor type | Xeon E3-1268L v3 (4C/8T, 2.3 (3.3) GHz, 8 MB cache); Core i5-4570TE (2C/4T, 2.7 (3.3) GHz, 4 MB cache); Core i3-4330TE (2C/4T, 2.4 GHz, 4 MB cache) |
| Chipset | Intel DH82C226 PCH |
| Interfaces/bus type | 1x COM1, 1x COM2 (optional), 1x LPT (optional), 2x DisplayPort, 1x DVI-I, 2x PS/2, audio (Microphone In, Line Out), 7x USB, 2x Gigabit Ethernet, PROFIBUS or PROFINET optional |
| Serial interface | COM1: 1x RS 232, COM2 (optional): 1x RS 232 |
| Industrial Ethernet interface | – 1000 Mbps |
| IP (at the front) | IP41 |
Frequently Asked Questions
What is the exact Siemens model designation for 6AG4112-2GA23-1XX5?
The product type designation is IPC647D.
What form factor and mounting arrangement does this IPC647D have?
It is a Rack PC, 19", 2U, for horizontal installation, prepared for telescopic rails, with a 19" mounting bracket that can be removed externally.
Which power supply specification is listed for 6AG4112-2GA23-1XX5?
The supply voltage is 100/240 V AC (autorange) 50 / 60 Hz, with optional redundant 100/240 V AC.
Which communication interfaces are included on this IPC647D?
It includes 2x Gbit Ethernet (IE/PN), 2x DisplayPort, 1x DVI-I, 1x COM1, 2x PS/2, audio, and USB interfaces, with PROFIBUS or PROFINET optional.